In-Line Bypass
Water Cut Analyzer

Model Number:
Configuration:
Pipeline Diameter:
Starting From:
DC-1510
Flow-Through
3/4" - 2"
$18,640
GET CUSTOM QUOTEDOWNLOAD BROCHURE
*all prices shown are in USD
The DC-1510 Series is an in-line or by-pass style of Watercut Monitor.  It is available with 1″ or 2″ flanged process connections ranging from 150 to 1500# ANSI pressure ratings.  For non-flanged applications, we offer 3/4″ or 1″ NPT threaded ports.

The device may be oriented in either a vertical or horizontal direction, with process flanges located on the same or opposing sides.  This installation flexibility helps piping designers avoid placement of the instrument in a gas trap or water trap.

General Information

+

TARGET FLOW RATES: 1m³ to 10m³ per hour (either direction)
ORIENTATION: Horizontal or Vertical
PIPELINE DIAMETER:  3/4″ to 2″
CALIBRATION: Built-in Sample Ports, 3/4″ or 1″ NPT
PROCESS CONNECTIONS: 3/4″ or 1″ NPT, 1″ to 2″ Flanged – 150# to 1500# ANSI

Specifications

+

OPERATING PRINCIPLE: Advanced Digital Capacitance
WATER IN OIL RANGE: 0-50% (Standard) 0-90% (SAGD)
RESOLUTION:  0.001%
REPEATABILITY AND PRECISION: Up to 0.01%
TEMPERATURE VARIATIONS: Auto-Compensated from 0°C to 260°C
STANDARD WETTED PARTS: 316/316L SS
OPTIONAL WETTED PARTS: Duplex 2205, Inconel 625, Monel 400, Super Duplex 2507
STANDARD O-RING MATERIAL: Viton A
OPTIONAL O-RING MATERIAL: Nitrile, PTFE, Kalrez
STANDARD PROCESS FLUID TEMPERATURE: 135°C Maximum
OPTIONAL PROCESS FLUID TEMPERATURE: 260°C Maximum
AMBIENT TEMPERATURE (ELECTRONICS): -40 to 85°C
TRANSMITTER MOUNTING: Integral with sensor
STANDARD ELECTRICAL ENCLOSURE: Anodized Aluminum
OPTIONAL ELECTRICAL ENCLOSURE: 316/316L SS
CORROSION PROTECTION: NACE MR-0175/ISO 15156 2009, Sour service compliant
HAZARDOUS AREA CLASS: ETL: Class I, Zone 1, Ex d IIB; ATEX: Ex II 2 G, Ex d IIB T4 Gb; IECEx: Ex d IIB T4 Gb
STANDARD TEMPERATURE CLASS: T4 @ Max 135°C Process Fluid Temp.
HIGH TEMPERATURE CLASS: T140°C @ Max 260°C Process Fluid Temp.
INGRESS PROTECTION: IP66
CRN'S: Alberta, Manitoba
POWER SUPPLY: 24VDC @ 150mA floating
ELECTRICAL CONNECTIONS: (1) 1" NPT & (1) M25
HUMIDITY PROTECTION: Conformal coated CB
ANALOG: 4-20mA DC, isolated, self-powered
RS-232: 9600 baud, max. 100m
RS-485: 9600 baud, max. 1500m
MAXIMUM LOAD: 600 ohm load to control room
ISOLATION VOLTAGE: 500 volts peak
RELAY CONTACTS: SPST-NO 2A @ 24 VDC, non-inductive
ADJUSTABLE DELAY: One second increments
ACCESSORIES: Data Logger, 4-20mA Digital Loop Indicator

Installation Examples

+
View Diagram
View Diagram
View Diagram