The DC-1510 Series is an in-line or by-pass style of Watercut Monitor.  It is available with 1" or 2" flanged process connections ranging from 150 to 1500# ANSI pressure ratings.  For non-flanged applications, we offer 3/4" or 1" NPT threaded ports.

The device may be oriented in either a vertical or horizontal direction, with process flanges located on the same or opposing sides.  This installation flexibility helps piping designers avoid placement of the instrument in a gas trap or water trap.


DC-1510 ISO view.png

GENERAL INFORMATION

FLOW TARGET FLOW RATES
Either Direction 1m³ to 10m³ per hour
   
ORIENTATION PIPELINE DIAMETER
Horizontal or Vertical 3/4" to 2"
   
CALIBRATION PROCESS CONNECTIONS
Built-in Sample Ports 3/4" or 1" NPT
Available in 3/4" or 1" NPT 1" to 2" Flanged - 150# to 1500# ANSI

INSTALLATION EXAMPLES

 
 

GENERAL SPECIFICATIONS

Operating Principle: Advanced digital capacitance
Water in Oil Range: 0-50% (Standard)
0-90% (SAGD)
Resolution: 0.001%
Repeatability & Precision: Up to 0.01%
Temperature Variation: Auto-compensated from 0°C to 260°C
Standard Wetted Parts: 316/316L SS
Optional Wetted Parts: Duplex 2205, Inconel 625,
Monel 400, Super Duplex 2507
Standard O-ring Material: Viton A
Optional O-ring Material: Nitrile, PTFE, Kalrez
Standard Process Fluid Temperature: 135°C Maximum
Optional Process Fluid Temperature: 260°C Maximum
Ambient Temperature (electronics): -40 to 85°C
Transmitter Mounting: Integral with sensor
Standard Electrical Enclosure: Anodized Aluminum
Optional Electrical Enclosure: 316/316L SS
Corrosion Protection: NACE MR-0175/ISO 15156 2009
Sour service compliant
Hazardous Area Class: ETL: Class I, Zone 1, Ex d IIB
ATEX: Ex II 2 G, Ex d IIB T4 Gb
IECEx: Ex d IIB T4 Gb
Standard Temperature Class: T4 @ Max 135°C Process Fluid Temp.
High Temperature Class: T140°C @ Max 260°C Process Fluid Temp.
Ingress Protection: IP66
CRN’s: Alberta, Manitoba
Power Supply: 24 VDC @ 150mA floating
Electrical Connections: (1) 1” NPT & (1) M25
Humidity Protection: Conformal coated CB
Analog: 4-20mA DC, isolated, self-powered
RS-232: 9600 baud, max. 100m
RS-485: 9600 baud, max. 1500m
Maximum Load: 600 ohm load to control room
Isolation Voltage: 500 volts peak
Relay Contacts: SPST-NO 2A @ 24 VDC, non-inductive
Adjustable Delay: One second increments
Accessories: Data Logger
4-20mA Digital Loop Indicator